“配(pei)(pei)電(dian)箱”,也叫配(pei)(pei)電(dian)柜,是(shi)電(dian)動機控制中心的統稱。配(pei)(pei)電(dian)箱是(shi)按(an)電(dian)氣接線要(yao)求將開關設(she)備、測量儀(yi)表、保護(hu)電(dian)器和(he)輔助(zhu)設(she)備組裝在封閉(bi)或半(ban)封閉(bi)金屬柜中或屏幅上(shang),構(gou)成低(di)壓配(pei)(pei)電(dian)裝置。

便(bian)于管(guan)理,當發生電(dian)(dian)路故(gu)障時(shi)有利于檢修(xiu)。配電(dian)(dian)箱和(he)配電(dian)(dian)柜配電(dian)(dian)盤配電(dian)(dian)憑(ping)等(deng),是(shi)集中安裝開關、儀表等(deng)設備的成(cheng)套裝置。

配電箱的用途(tu)


  便于管理,當發生電路故障時有利于檢修。配(pei)電箱和配(pei)電柜配(pei)電盤配(pei)電憑等,是集中安裝(zhuang)開關、儀表等設備的成套裝(zhuang)置(zhi)。

常用(yong)(yong)的配電(dian)箱有木制和鐵板制兩種,現在(zai)哪兒的用(yong)(yong)電(dian)量都挺大的,所以還是(shi)鐵的用(yong)(yong)的比較多。

 配(pei)電箱(xiang)的用(yong)途(tu):當然是(shi)方便停、送電,起到計量和判斷停、送電的作用(yong)。

配電箱構(gou)成(cheng)


主要分為兩部分:

一(yi)是成套部(bu)件,即配(pei)電箱外(wai)殼及其相關配(pei)件。
二是(shi)電氣元(yuan)件(jian)(jian)及相關附件(jian)(jian),即空氣開(kai)關和其所(suo)需要的附件(jian)(jian)。
一、斷路(lu)器

斷路器:既(ji)開(kai)關(guan)(guan),是配電柜(ju)的(de)主(zhu)要元器件,常用的(de)有空氣開(kai)關(guan)(guan)、漏電開(kai)關(guan)(guan)、雙電源自動轉換開(kai)關(guan)(guan)。

A、空氣開關的概念:

空氣(qi)開關(guan)也就是空氣(qi)斷(duan)路(lu)(lu)器,在電路(lu)(lu)中作接通、分(fen)斷(duan)和(he)承載(zai)(zai)額(e)定工作電流和(he)短(duan)路(lu)(lu)、過載(zai)(zai)等故障電流,并能在線路(lu)(lu)和(he)負載(zai)(zai)發生過載(zai)(zai)、短(duan)路(lu)(lu)、欠(qian)壓等情況下,迅速分(fen)斷(duan)電路(lu)(lu),進行可靠的保護(hu)。
斷(duan)(duan)路(lu)(lu)器(qi)的(de)(de)動、靜觸(chu)(chu)頭及(ji)觸(chu)(chu)桿設計型式多樣,但(dan)提高斷(duan)(duan)路(lu)(lu)器(qi)的(de)(de)分斷(duan)(duan)能力是主要目(mu)的(de)(de)。目(mu)前,利用(yong)一定的(de)(de)觸(chu)(chu)頭結構,限(xian)制分斷(duan)(duan)時短路(lu)(lu)電流峰值的(de)(de)限(xian)流原理,對提高斷(duan)(duan)路(lu)(lu)器(qi)的(de)(de)分斷(duan)(duan)能力有明(ming)顯(xian)的(de)(de)作用(yong),而被廣泛采(cai)用(yong)。

B、空(kong)氣(qi)開關的工作原理:

自動空氣開關也稱為低壓斷路器,可用來接通和分斷負載電路,也可用來控制不頻繁起動的電動機。它功能相當于閘刀開關、過電流繼電器、失壓繼電器、熱繼電器及漏電保護器等電器部分或全部的功能總和,是低壓配電網中一種重要的保護電器。

自(zi)動空氣開關(guan)具有多種(zhong)保護(hu)功(gong)能(過載、短路、欠(qian)電壓(ya)保護(hu)等(deng))、動作(zuo)值可調、分斷(duan)能力高、操作(zuo)方(fang)便、安(an)全等(deng)優點,所以(yi)目(mu)前被廣(guang)泛(fan)應用。

2、漏電保護開關:

A、漏電保護開關概念:
既具備(bei)漏(lou)電保(bao)護(hu)(hu)(hu)功能(neng),人(ren)觸(chu)摸到帶電體會跳閘,確保(bao)人(ren)身安全,是漏(lou)電保(bao)護(hu)(hu)(hu)器(qi)的主要功能(neng);用電設備(bei)如果絕緣(yuan)不好(hao)漏(lou)電到外(wai)殼上,漏(lou)電保(bao)護(hu)(hu)(hu)器(qi)也會跳閘,避免人(ren)體觸(chu)摸觸(chu)電。同時具備(bei)電流通斷功能(neng)、過負荷保(bao)護(hu)(hu)(hu)和短路保(bao)護(hu)(hu)(hu)功能(neng)。

B、漏(lou)電(dian)保護開(kai)關的(de)工作(zuo)原(yuan)理:

漏電(dian)保(bao)護器(qi)的(de)工(gong)作原理圖。LH為零序電(dian)流互感(gan)(gan)器(qi),它由坡莫合金為材(cai)料的(de)鐵芯,和繞在環狀鐵芯上的(de)二次(ci)線(xian)(xian)圈(quan)組成檢測(ce)元件。電(dian)源(yuan)相線(xian)(xian)和中性線(xian)(xian)穿過(guo)圓孔成為零序互感(gan)(gan)器(qi)的(de)一次(ci)線(xian)(xian)圈(quan)。互感(gan)(gan)器(qi)的(de)后部(bu)出(chu)線(xian)(xian)即為保(bao)護范圍。

C、漏(lou)電保護開關的作用:
(1)、當電(dian)氣設(she)備(bei)或(huo)線路發生漏電(dian)或(huo)接(jie)地故障時,能在人尚未觸(chu)及之前就把電(dian)源切斷。
(2)、當人體(ti)觸及帶電(dian)的物體(ti)時,能在0.1s內切斷(duan)電(dian)源,從而(er)減(jian)輕電(dian)流對人體(ti)的傷害程度。
(3)、可以防止因漏電而引起的火災事故(gu)。

3、雙電源自動轉換開關:

概念:雙電源(yuan)自(zi)(zi)動(dong)轉換(huan)開關為電源(yuan)二選一(yi)自(zi)(zi)動(dong)切換(huan)系統,第(di)(di)一(yi)路(lu)出現故障后雙電源(yuan)自(zi)(zi)動(dong)轉換(huan)開關自(zi)(zi)動(dong)切換(huan)到第(di)(di)二路(lu)給負(fu)載(zai)供(gong)電,第(di)(di)二路(lu)故障的話雙電源(yuan)自(zi)(zi)動(dong)轉換(huan)開關自(zi)(zi)動(dong)切換(huan)到第(di)(di)一(yi)路(lu)給負(fu)載(zai)供(gong)電。
適合用于UPS-UPS,UPS-發電機,UPS-市電,市電-市電等任意兩路電源的不斷電轉換。

二、浪涌保護器
A、浪涌保護器的概念:
浪(lang)涌保護器(qi),也(ye)叫防雷器(qi),是一種為各種電(dian)子(zi)(zi)設(she)備、儀(yi)器(qi)儀(yi)表(biao)、通訊線路(lu)提供安(an)全防護的(de)電(dian)子(zi)(zi)裝置。當電(dian)氣回路(lu)或者通信(xin)線路(lu)中因為外界的(de)干擾突然產生尖(jian)峰電(dian)流或者電(dian)壓時(shi),浪(lang)涌保護器(qi)能(neng)在極短(duan)的(de)時(shi)間內(nei)導通分流,從而避免浪(lang)涌對回路(lu)中其他設(she)備的(de)損害。

B、浪(lang)涌基本知識:

浪涌保護器系統的主要作用是保護電子設備免受“浪涌”的損害。因此,如果您想知道浪涌保護器的作用,就需要弄清楚兩個問題:什么是浪涌?電子設備為什么需要它們的保護?

浪涌也叫突波,顧名思義就是超出正常工作電壓的瞬間過電壓。本質上講,浪涌是發生在僅僅幾百萬分之一秒時間內的一種劇烈脈沖。可能引起浪涌的原因有:重型設備、短路、電源切換或大型發動機。

電(dian)(dian)涌或瞬變電(dian)(dian)壓是(shi)指電(dian)(dian)壓在(zai)電(dian)(dian)能流(liu)動的過程中大幅超過其額定水平(ping)。

在美國,一般家庭和辦公環境配線的(de)標準電壓是120伏。如果電壓超過了120伏,就會(hui)產生(sheng)問(wen)題(ti),而浪涌保護器有助(zhu)于防止(zhi)該問(wen)題(ti)損壞計算機。

C、浪涌保護(hu)器(qi)的作用:

第(di)一(yi)道防線應是連接在(zai)用(yong)戶供電(dian)系統入口進線各相(xiang)和(he)大(da)(da)地之間的(de)(de)大(da)(da)容量電(dian)源(yuan)防浪涌(yong)保(bao)護(hu)(hu)器(qi)。一(yi)般要(yao)(yao)求該級電(dian)源(yuan)保(bao)護(hu)(hu)器(qi)具備100KA/相(xiang)以(yi)上的(de)(de)最大(da)(da)沖擊容量,要(yao)(yao)求的(de)(de)限制(zhi)電(dian)壓(ya)應小于2800V。我們(men)稱(cheng)為CLASS I 級電(dian)源(yuan)防浪涌(yong)保(bao)護(hu)(hu)器(qi) (簡(jian)稱(cheng)SPD)。

這些電源防浪涌保護器是專為承受雷電和感應雷擊的大電流和高能量浪涌能量吸收而設計的,可將大量的浪涌電流分流到大地。它們僅提供限制電壓(沖擊電流流過SPD時,線路上出現的最大電壓成為限制電壓)為中等級別的保護,因為CLASS I 級的保護器主要是對大浪涌電流的吸收。僅靠它們是不能完全保護供電系統內部的敏感用電設備。

第二道防線應該是安裝在向重要或敏感用電設備供電的分路配電設備處的電源防浪涌保護器。

這些SPD對于通過了用戶供電入口浪涌放電器的剩余浪涌能量進行更完善的吸收,對于瞬態過電壓具有極好的抑制作用。該處使用的電源防浪涌保護器要求的最大沖擊容量為40KA/相以上,要求的限制電壓應小于2000V。我們稱為CLASS II 級電源防浪涌保護器。一般的用戶供電系統作到第二級保護就可以達到用電設備運行的要求了。

最后的防線可在用電設備內部電源部分使用一個內置式的電源防浪涌保護器,以達到完全消除微小瞬態的瞬態過電壓的目的。

該處使用的(de)電源防(fang)浪涌保護(hu)(hu)(hu)器(qi)要(yao)求的(de)最大沖擊容(rong)量(liang)為20KA/相或(huo)更低(di)一些,要(yao)求的(de)限制電壓應小(xiao)于1800V。對于一些特別重要(yao)或(huo)特別敏感的(de)電子(zi)設備,具備第三級的(de)保護(hu)(hu)(hu)是必要(yao)的(de)。同時也可(ke)以保護(hu)(hu)(hu)用電設備免受系統內部(bu)產生(sheng)的(de)瞬態過電壓影響。

三、電度表

A、電度表的概念:
電工通(tong)常用的電能表(biao)(biao),是用來測(ce)量電能的儀表(biao)(biao),俗稱電度表(biao)(biao)。

B、電度表的工作原(yuan)理:

①機械電度表工作原理:
當電(dian)能表接入電(dian)路(lu)時(shi),電(dian)壓線圈和電(dian)流線圈產生的磁(ci)通(tong)(tong)穿過(guo)圓盤,這些磁(ci)通(tong)(tong)在時(shi)間和空間上不(bu)同相(xiang),分別在圓盤上感應(ying)出渦流。
由于磁通(tong)與渦(wo)流的相互作用而(er)產生轉(zhuan)動力(li)矩使圓盤轉(zhuan)動,因磁鋼的制動作用,使圓盤的轉(zhuan)速達(da)到勻速運動。
由于磁通(tong)與(yu)電(dian)路(lu)中(zhong)的(de)電(dian)壓(ya)和電(dian)流成正(zheng)比例(li),使(shi)圓(yuan)(yuan)盤在其作用下以正(zheng)比于負載電(dian)流的(de)轉速運動(dong),圓(yuan)(yuan)盤的(de)轉動(dong)經(jing)蝸桿(gan)傳(chuan)動(dong)到(dao)計度器,計度器的(de)示數就是電(dian)路(lu)中(zhong)實際所使(shi)用的(de)電(dian)能。

②電子(zi)電度(du)表基本原理:

電(dian)(dian)(dian)子(zi)(zi)式電(dian)(dian)(dian)度表(biao)是(shi)利用電(dian)(dian)(dian)子(zi)(zi)電(dian)(dian)(dian)路/芯(xin)片(pian)來測(ce)量(liang)電(dian)(dian)(dian)能;用分壓電(dian)(dian)(dian)阻或電(dian)(dian)(dian)壓互感(gan)器將(jiang)電(dian)(dian)(dian)壓信號(hao)變(bian)成(cheng)(cheng)可(ke)用于電(dian)(dian)(dian)子(zi)(zi)測(ce)量(liang)的(de)小信號(hao),用分流器或電(dian)(dian)(dian)流互感(gan)器將(jiang)電(dian)(dian)(dian)流信號(hao)變(bian)成(cheng)(cheng)可(ke)用于電(dian)(dian)(dian)子(zi)(zi)測(ce)量(liang)的(de)小信號(hao),利用專用的(de)電(dian)(dian)(dian)能測(ce)量(liang)芯(xin)片(pian)將(jiang)變(bian)換好的(de)電(dian)(dian)(dian)壓、電(dian)(dian)(dian)流信號(hao)進行模擬或數字乘法,并對電(dian)(dian)(dian)能進行累計,然后輸出頻率(lv)與電(dian)(dian)(dian)能成(cheng)(cheng)正比的(de)脈沖信號(hao);
脈沖信號驅動(dong)(dong)步(bu)進馬達帶動(dong)(dong)機械計度器顯示,或(huo)送微計算(suan)機處(chu)理(li)后(hou)進行數碼顯示。

四、電流表
A、電流表的工作原理:
流表(biao)是跟(gen)據(ju)通(tong)電(dian)導體(ti)在磁(ci)場中(zhong)受(shou)磁(ci)場力的(de)作用(yong)而制成的(de)。當有(you)電(dian)流通(tong)過時,電(dian)流沿(yan)彈簧、轉軸(zhou)通(tong)過磁(ci)場,電(dian)流切磁(ci)感線(xian),所以受(shou)磁(ci)場力的(de)作用(yong),使線(xian)圈發生偏(pian)轉,帶動(dong)轉軸(zhou)、指針偏(pian)轉。
由于磁(ci)場(chang)力(li)的(de)大(da)小隨電(dian)流(liu)增大(da)而(er)增大(da),所以就可以通過指針(zhen)的(de)偏轉程度來觀察電(dian)流(liu)的(de)大(da)小。 這叫磁(ci)電(dian)式電(dian)流(liu)表。

B、電(dian)流表的使用規則:

①電(dian)流表要串聯(lian)在電(dian)路中(否則(ze)短路。
②被測電(dian)流不要超(chao)過電(dian)流表的量程(可以采用(yong)試(shi)觸(chu)的方法來看是否(fou)超(chao)過量程。
③絕(jue)對不允許不經過用電(dian)器而把電(dian)流(liu)(liu)表(biao)連(lian)到電(dian)源(yuan)的兩極上(電(dian)流(liu)(liu)表(biao)內阻很小,相(xiang)當(dang)于一根(gen)導線。若將電(dian)流(liu)(liu)表(biao)連(lian)到電(dian)源(yuan)的兩極上,輕則指(zhi)針打(da)歪,重(zhong)則燒壞電(dian)流(liu)(liu)表(biao)、電(dian)源(yuan)、導線。
④看(kan)清表(biao)針停留位置(一(yi)定從正面(mian)觀察(cha))

五、電壓表
A、電(dian)壓表的概念:
電(dian)壓表是(shi)測量電(dian)壓的(de)(de)一種儀(yi)器,常用電(dian)壓表——伏(fu)特表符(fu)號:V,在靈敏電(dian)流計(ji)里面有一個(ge)(ge)永磁(ci)體,在電(dian)流計(ji)的(de)(de)兩個(ge)(ge)接線(xian)柱之間串聯一個(ge)(ge)由導線(xian)構成的(de)(de)線(xian)圈,線(xian)圈放置在永磁(ci)體的(de)(de)磁(ci)場中,并通過(guo)傳動裝置與(yu)表的(de)(de)指(zhi)針(zhen)相(xiang)連。電(dian)壓表是(shi)個(ge)(ge)相(xiang)當大(da)的(de)(de)電(dian)阻器,理想的(de)(de)認(ren)為(wei)是(shi)斷(duan)路。

B、電壓表工(gong)作原理:

電壓表是采用電流表裝配的,電流表的內阻很小,那么串連一個大的電阻,就可以直接并接到需要量取電壓的兩點,根據歐姆定律的關系可以知道,電流表顯示的電流正比于外部電壓,所以就可以測量出電壓了。

C、電壓(ya)表的使用:
電(dian)壓(ya)(ya)表能直(zhi)接(jie)測(ce)電(dian)源電(dian)壓(ya)(ya),電(dian)壓(ya)(ya)表使(shi)用(yong)時(shi)(shi)要并聯(lian)在電(dian)路中。使(shi)用(yong)電(dian)壓(ya)(ya)表時(shi)(shi)應注(zhu)意以(yi)下幾點:
(1)測電(dian)壓時(shi),必須把電(dian)壓表并聯在被測電(dian)路的(de)兩端;
(2)正確選擇量(liang)程(cheng),被測電壓不(bu)要(yao)超過電壓表的量(liang)程(cheng)。使用時并聯在電路中(zhong);如果串(chuan)聯,則測得的是電源電動(dong)勢(shi)。

不過以上講到的幾種元(yuan)器(qi)件都是配(pei)電(dian)(dian)箱中最基本的元(yuan)器(qi)件,在實(shi)際生產(chan)過程中還會根(gen)據配(pei)電(dian)(dian)箱不同的用途(tu),以及對配(pei)電(dian)(dian)箱的使用要求來增加其他的元(yuan)器(qi)件,如:交流(liu)接觸器(qi)、中間(jian)繼電(dian)(dian)器(qi)、時間(jian)繼電(dian)(dian)器(qi)、按鈕、信號指示燈、KNX智能開關模(mo)塊(帶容性負載(zai))及后臺監(jian)(jian)控系(xi)統、智能消防疏散照(zhao)明及后臺監(jian)(jian)控系(xi)統、電(dian)(dian)氣(qi)火災(zai)/漏電(dian)(dian)監(jian)(jian)控探(tan)測器(qi)及后臺監(jian)(jian)控系(xi)統、EPS電(dian)(dian)源電(dian)(dian)池等(deng)等(deng)。


配電(dian)箱的安(an)裝要求(qiu)

1、配(pei)電箱(xiang)應用(yong)不可燃(ran)材料制作;
2、觸電危險性小的(de)生產場(chang)所和辦公室,可安裝開啟式的(de)配電板;
3、在觸電危險性大或作業環境較差的加工車間、鑄造、鍛造、熱處理、鍋爐房、木工房等場所,應安裝封閉式箱柜;
4、在有導(dao)電性粉塵或(huo)產(chan)生易燃易爆氣體的危險(xian)作業場所,必須安裝密閉式或(huo)防爆型的電氣設(she)施;
5、配電(dian)(dian)箱各電(dian)(dian)氣元件、儀(yi)表(biao)、開關和線路應(ying)排列整齊,安(an)裝牢固,操作方便;
6、落地安(an)裝的板(箱)底(di)面應(ying)高(gao)出(chu)地面5~10 mm;
7、操作手柄中心高度一般(ban)為1.2~1.5m;
8、箱前方0.8~1.2m的范圍內無障礙物;
9、保(bao)護線連接可靠;
10、箱以外不得有裸帶電體外露;

11、必須(xu)裝設在箱(xiang)外(wai)表面或配(pei)電板上(shang)的(de)電氣(qi)元件,必須(xu)有可靠的(de)屏護。


配(pei)電柜的操(cao)作規程

(1)配電柜為船舶配電中樞八產和設備的正常運轉,任何無關人員不得扳動板上的開關。

(2)發電機組啟動后,應利用動力屏升速開關手動緩慢加速,直到發電機進入正常工作狀態,電壓與頻率達到規定值,方可合閘送電。

(3)配電板進入配電狀態后,不得隨意拔動動力屏升速開關,空氣斷路器的閉鎖開關非緊急情況不得使用。

(4)發電機并聯運行要嚴格按照并車條件要求與規定進行操作,要注意出現逆功率(逆流)和并車失敗等現象。

(5)停機時應先切斷發電機負荷,然后空載停車,不得帶負荷直接停機。

(6)交插岸電時,應先切斷岸電屏各動力開關,然后檢查接線與相序的正確性,確認正確后,方可實施船岸電的轉換,嚴禁帶負荷操作。

(7)配電柜應定期進行清潔和維護保養工作,以便使設備始終處于良好的工作狀態。

(8)發電(dian)機工作,輪機人員進行配電(dian)板(ban)操作時(shi),應集中思想,謹慎操作,防止意外事(shi)故(gu)發生,否(fou)則將(jiang)追究(jiu)個人事(shi)故(gu)責任。

(9)充(chong)放電(dian)板(ban)為船舶應急配電(dian)板(ban),當班輪機人(ren)員應經(jing)常檢查其(qi)工作(zuo)(zuo)狀況,隨時(shi)保證低(di)壓(ya)電(dian)力(li)充(chong)足,并(bing)通(tong)過板(ban)上(shang)儀表掌握磁(ci)飽和(he)穩壓(ya)器的工作(zuo)(zuo)狀況。

(10)正常航行(xing)時,配電板上各路開關應處于接通,以保證發電機能(neng)隨時啟動及應照時能(neng)隨時投入使(shi)用。

二次接線流程

1、按(an)照原理圖來了,不在同一位置的的要上端子(zi),千(qian)萬不要一個端子(zi)接3根線。查(cha)錯就不是那(nei)么查(cha)了,只能按(an)照原理圖來一個個對。
(1)導線橫截(jie)面的選用
市電(dian)(交流220V)電(dian)壓回路的線用(yong)1.5平方毫(hao)米(mi)的;電(dian)流回路用(yong)2.5平方毫(hao)米(mi)的。蓄電(dian)池一般用(yong)1.5平方毫(hao)米(mi)就可(ke)以(yi)。

(2)接(jie)線時(shi)候,要(yao)(yao)檢查(cha)好導線兩(liang)端的信號(hao)是否對應,以免造成不必要(yao)(yao)的錯誤。

(3)最(zui)主(zhu)要(yao)的是看明白原理圖及接(jie)線圖。
2、如果是新手要先審圖,整理一條(tiao)自(zi)己的(de)思路,而且還可以(yi)檢查一下圖紙(zhi)有(you)沒有(you)問題,不(bu)懂的(de)地方可以(yi)先弄明白,這樣有(you)利(li)于做線。然后才開始接線。
對二次接線(xian)施工的要(yao)求:按(an)圖施工,接線(xian)正確;導線(xian)與(yu)電氣元件采用螺栓(shuan)連接、插接、焊(han)接或壓接等,均應牢固可靠(kao),接線(xian)良(liang)好;配(pei)線(xian)整齊清晰(xi)、美觀;導線(xian)絕緣良(liang)好,無損傷;柜內導線(xian)不應有接頭;回路(lu)編號正確,字跡清晰(xi)。
電纜芯線截面的選擇還應符合下列要求:

(1)電(dian)(dian)流(liu)回路:應使(shi)電(dian)(dian)流(liu)互感(gan)器的工作(zuo)準確(que)等(deng)級,此時,如(ru)無可靠根據,可按斷(duan)路器的電(dian)(dian)流(liu)容量確(que)定最(zui)大短路電(dian)(dian)流(liu)。

(2)電壓回路:當全部保護裝置和安全自動裝置動作時(考慮到發展,電壓互感器的負荷最大時),電壓互感器至保護和自動裝置屏的電纜壓降不應超過額定電壓的3%。
(3)操作(zuo)回(hui)路:在(zai)最大負荷(he)下,操作(zuo)母線至設(she)備的電壓降,不(bu)應超過10%額定電壓。

電流(liu)互感(gan)器二次(ci)繞組(zu)不(bu)允許(xu)開路,電壓互感(gan)器二次(ci)側(ce)不(bu)允許(xu)短路二次(ci)接線前,應熟悉一下圖紙(zhi):
(1)原理圖(表示(shi)各回(hui)路的工作(zuo)原理和(he)相互作(zuo)用。圖紙不(bu)久表示(shi)出(chu)二次回(hui)路中各元件的連接方式,而且(qie)還表示(shi)出(chu)與一次回(hui)路有關的聯系)
(2)展開圖
(3)端(duan)子排圖






快速聯系我們